Other Products |Vitalograph In2itive Spirometer

USD 1,074.92
Other Products / General Merchandise / Other Products
Vitalograph In2itive Spirometer
Vitalograph In2itive Spirometer Next generation In2itive Handheld 83002
A powerful and versatile respiratory diagnostics solution with wireless bi-directional EMR connectivity, enabling detailed, point-of-care spirometry testing wherever it is needed.
Powerful spirometry in the palm of your hand for accurate and connected testing, wherever it is needed.
The In2itive delivers detailed point-of-care spirometry that is compliant with ATS/ERS 2019 Technical Standards for accuracy and test quality.
Ideal for use throughout all healthcare settings, the In2itive has an easy-to-navigate interface and can store more than 20,000 tests. Its robust, detachable flowhead is suited to a variety of testing scenarios. A large touch screen enables the clinician to actively coach the patient during testing and to give real-time feedback on effort and test quality.
Bi-directional EMR connectivity continuously synchronises respiratory assessment needs and spirometry results, to maximise the efficiency of healthcare decisions.

Test Modules

Description

Parameters

Onscreen Graphs

Forced Vital Capacity

The total volume of air that can be exhaled during a maximal forced expiration effort.

FVC, FEV1, FEF25-75, PEF, etc

Flow/Volume/Time

Volume/Time

Vital Capacity

The total volume of air that can be exhaled during a normal expiration effort.

VC, IC, IVC, TV

Bar Chart

Volume/Time

Bronchodilator Responsiveness Testing

Determines the degree of improvement of airflow in response to bronchodilator administration as measured by changes in FEV1 and FVC.

VC, FVC, FEV1, FEF25-75, PEF, etc

Pre-Post Flow/Volume

Pre-Post Volume

 
Product: Vitalograph In2itive
Model: 2120
Flow detection principle: Fleisch type pneumotachograph
Volume accuracy: +/- 2.5% ATS/ERS 2019, ISO 26782:2009
Flow accuracy: ±10% or ±10L/min of the reading (ISO 23747:2015)
Performance standards: ATS/ERS 2019, ISO 23747:2015 & ISO 26782:2009
Safety standards: EN 60601-1:2006 +A1:2013 +A2:2021 QA/GMP standards: EN ISO 13485, FDA 21 CFR 820, CMDR SOR/98-282 and Japan's PMD Act
Dimensions: 186mm x 81mm x 48mm
Weight: 300g
Communications: USB 2.0 & Wi-Fi
Power Supply: 3.7V, 2Ahr Lithium Polymer battery
Parameters measured: EVC, IVC, FRC, VC, FVC, FIVC/ FVC, FEV0.5 , FEV0.5 /FVC, FEV0.75 , FEV0.75 /FVC, FEV1 , FEV1 R, FEV1 /VC, FEV1 /EVC, FEV1 /FVC, FEV1 /FIVC, FEV1 /FEV6 , FEV1 /PEF, FEV3 , FEV3 /VC, FEV3 /FVC, FEV6 , PEF L/s, PEF L/min, FEV25 , FEF50 , FEF75 , FEF0.2-1.2, FEF25-75 , FIV1 , FIV1 / FVC, FIV1 /FIVC, PIF L/s, PIF L/min, FIF25 , FIF50 , FIF75 , FEF50FIF50 , MVVind, FMFT, FET, FRC, TV, RV, TLC, IRV, ERV, IC, Rind, ELA, tPEF, Text, BEV, BEV/FVC, EOTV, tRISE, tHES, FIVC, FEV1 /FVC, FEF25-75 /FVC, FEF75-85 , FIF50-FEF50
Brand:VitalographSKU:ECO03242
View product
Product details
Vitalograph In2itive Spirometer
Vitalograph In2itive Spirometer Next generation In2itive Handheld 83002
A powerful and versatile respiratory diagnostics solution with wireless bi-directional EMR connectivity, enabling detailed, point-of-care spirometry testing wherever it is needed.
Powerful spirometry in the palm of your hand for accurate and connected testing, wherever it is needed.
The In2itive delivers detailed point-of-care spirometry that is compliant with ATS/ERS 2019 Technical Standards for accuracy and test quality.
Ideal for use throughout all healthcare settings, the In2itive has an easy-to-navigate interface and can store more than 20,000 tests. Its robust, detachable flowhead is suited to a variety of testing scenarios. A large touch screen enables the clinician to actively coach the patient during testing and to give real-time feedback on effort and test quality.
Bi-directional EMR connectivity continuously synchronises respiratory assessment needs and spirometry results, to maximise the efficiency of healthcare decisions.

Test Modules

Description

Parameters

Onscreen Graphs

Forced Vital Capacity

The total volume of air that can be exhaled during a maximal forced expiration effort.

FVC, FEV1, FEF25-75, PEF, etc

Flow/Volume/Time

Volume/Time

Vital Capacity

The total volume of air that can be exhaled during a normal expiration effort.

VC, IC, IVC, TV

Bar Chart

Volume/Time

Bronchodilator Responsiveness Testing

Determines the degree of improvement of airflow in response to bronchodilator administration as measured by changes in FEV1 and FVC.

VC, FVC, FEV1, FEF25-75, PEF, etc

Pre-Post Flow/Volume

Pre-Post Volume

 
Product: Vitalograph In2itive
Model: 2120
Flow detection principle: Fleisch type pneumotachograph
Volume accuracy: +/- 2.5% ATS/ERS 2019, ISO 26782:2009
Flow accuracy: ±10% or ±10L/min of the reading (ISO 23747:2015)
Performance standards: ATS/ERS 2019, ISO 23747:2015 & ISO 26782:2009
Safety standards: EN 60601-1:2006 +A1:2013 +A2:2021 QA/GMP standards: EN ISO 13485, FDA 21 CFR 820, CMDR SOR/98-282 and Japan's PMD Act
Dimensions: 186mm x 81mm x 48mm
Weight: 300g
Communications: USB 2.0 & Wi-Fi
Power Supply: 3.7V, 2Ahr Lithium Polymer battery
Parameters measured: EVC, IVC, FRC, VC, FVC, FIVC/ FVC, FEV0.5 , FEV0.5 /FVC, FEV0.75 , FEV0.75 /FVC, FEV1 , FEV1 R, FEV1 /VC, FEV1 /EVC, FEV1 /FVC, FEV1 /FIVC, FEV1 /FEV6 , FEV1 /PEF, FEV3 , FEV3 /VC, FEV3 /FVC, FEV6 , PEF L/s, PEF L/min, FEV25 , FEF50 , FEF75 , FEF0.2-1.2, FEF25-75 , FIV1 , FIV1 / FVC, FIV1 /FIVC, PIF L/s, PIF L/min, FIF25 , FIF50 , FIF75 , FEF50FIF50 , MVVind, FMFT, FET, FRC, TV, RV, TLC, IRV, ERV, IC, Rind, ELA, tPEF, Text, BEV, BEV/FVC, EOTV, tRISE, tHES, FIVC, FEV1 /FVC, FEF25-75 /FVC, FEF75-85 , FIF50-FEF50